Arizona Department of Health Services Home Page Banner
 
Office Home Page > Environmental Home Page
   
Bureau of State Laboratory Services
AZPDES and APP Field Method Information
 

The Arizona Department of Health Services (ADHS) Environmental Laboratory Licensure program has put this page together to provide information for Facilities with AZPDES and APP permits that need additional information regarding use of licensed laboratories or becoming licensed by the Office of Laboratory Services.

At any time, you may contact the Office of Laboratory Services at (602) 364-0720 for assistance.


Environmental Licensure Information

Letter from ADHS to WWTP Facilities - March 2010PDF

Letter from ADEQ to AZPDES Permit Holders - March 2010PDF

Arizona List of Licensed Laboratories with Parameters - A list of all laboratories licensed by the state of Arizona for testing of drinking water, wastewater, solid waste and air.

Statutes (Title 36 Chapter 4.3) and RulesPDF for Arizona Environmental Laboratory Licensure

Application for Licensure - Instructions and forms for applying to become licensed in the state of Arizona.

Environmental Laboratory Advisory Committee (ELAC) - The committee meets quarterly to discuss rules and other technical issues affecting the licensed laboratories and various regulatory agencies.


Checklists, Spreadsheets, Example Bench Sheets, and SOP Templates

The ADHS Environmental Laboratory Licensure program has made every effort to ensure the accuracy of the information provided in the following checklists, spreadsheets, and bench sheets.  The following are to be used as tools to assist facilities in performing the approved methods correctly.  Please read the disclaimerPDF prior to using any of the spreadsheets or bench sheets. The checklists are provided as examples of what surveyors will be looking for when performing an on site visit.

The Quality Assurance/Quality Control document is required for all wastewater exempt methods compliance testing.

Temperature FormExcel – Example of a form used for taking temperature of refrigerators and other equipment

Thermometer Calibration Formword – Example of a form used when calibrating thermometers

Method Detection Limit or MDL SpreadsheetExcel – Used to calculate MDL values

Linear Regression SpreadsheetExcel – Used to evaluate and calculate linear calibrations

Demonstration of CapabilityExcel - Used to calculate capability for operators during training of exempt methods

Bench Sheets
These are example bench sheets for the exempt methods.  Please note that there are two workbooks for each method, one for a single day worth of testing and one for multiple days.

pH (Hydrogen Ion): EPA 150.2Excel SM4500H-BExcel HACH 8156Excel
Turbidity:        EPA 180.1Excel  EPA 180.1 (LCR)Excel SM 2130BExcel
Conductivity:  EPA 120.1Excel SM 2510BExcel HACH 8160Excel
Chlorine*: HACH10014Excel HACH10014Word  

* These bench sheets were provided and posted with permission from the Pima County Regional Wastewater Department and Laboratory. The acceptance criteria of 90-110% for the standard check are not required by the method and facilities may change those criteria, as an example a facility changed the recovery to 70-130%.

SOP Templates
These are standard operating procedure (SOP) templates for the exempt methods. Please note that the templates are written for the most common exempt method seen in the field, but these templates can be used for other methods as long as the facility updates the method specific requirements.

Back to Top


Training Information

ADHS provided training in late spring 2010, late summer 2010, and August 2011, and has posted the training presentations and/or information below.  If you have any questions, please do not hesitate to contact our Office at (602) 364-0720.  These training classes provided basic information on the regulations and detailed discussions and demonstrations of the approved methodologies.

ADHS may provide additional training in the future, which will be posted here or you may contact our Office to be placed on a notification list.

ADHS has performed three rounds of wastewater plant training (AZPDES/APP/Reuse). These trainings occurred in Spring 2010, Fall 2010, and August 2011. The following presentations and videos were presented in these trainings and should be used as a guide for meeting permit compliance. Except where noted, presentations apply to any permit required to report compliance data to ADEQ (AZPDES/APP/Reuse).

DMRQA - For AZPDES onlyPDF IDEXX Colilert and QuantiTray PDF
Colilert and QuantiTray QCPDF Method Detection LimitsPDF
QAQC For Exempt MethodsPDFReport of Findings and ResponsesPDF
Temperature PDF | Video 1 Video 2 Specific Conductance PDF | Video
Dissolved Oxygen PDF | VideoTurbidity PDF | Video-Lab Video-InLine
ULR Total Residual Chlorine PDF | Video
pH (Hydrogen Ion) PDF | Video 

The following presentations and videos were given at a one day seminar provided in January 2012 specifically for mines with AZPDES and APP permits. Please note that these presentations apply to all permit types (AZPDES/APP).

QAQC For Exempt MethodsPDFTemperature PDF | Video 1
pH (Hydrogen Ion) PDF | VideoSpecific Conductance PDF | Video
Report of Findings and ResponsesPDF 

Back to Top


Method References

Provided below are the approved method references for exempt compliance testing. A complete list of approved methods is available by accessing our rules or application, see links in the Environmental Licensure Information section of the page. Please note that those methods that are available free of charge are provided on this page, all other methods are considered proprietary and must be purchased from the organization or company.

The Quality Assurance/Quality Control document is required for all wastewater exempt methods compliance testing.

Links to Individual Methods:

ADHS Web Privacy Policy. This page last modified on May 22, 2012 8:08 AM.
Copyright 2012 Arizona Department of Health Services. All rights reserved.
General comments, questions, or concerns:  Customer Feedback