This is a table of the various methods utilized by the Environmental Microbiology section at the State Public Health Lab.  Each method name is identified along with the units, standard method number, holding time and matrix. Table Date:

Method Name: Presence/Absence (P-A) Coliform Test; Units: Presence or Absence/100ml; Standard Method Number: SM 9221D; Holding Time: 30 hours; Matrix: Drinking, Well or Ground Water.

Method Name: Enzyme Substrate Coliform Test (Colilert/Colisure); Units: Presence or Absence/100ml; Standard Method Number: SM 9223B; Holding Time: 30 hours; Matrix: Drinking, Well or Ground Water.

Method Name: Colilert Most Probable Number (MPN) (Colitray); Units: MPN Index/100 ml; Standard Method Number: SM 9223B; Holding Time: 30 hours for Drinking, Well or Ground Water; Holding Time: 6 hours for Surface/Ambient and Wastewater; Matrix: Drinking, Well or Ground Water, Surface/Ambient and Wastewater.

Method Name: Fecal Coliform Membrane Filer (MF); Units: C.F.U./100 ml; Standard Method Number: SM 9222D and SM 9221E; Holding Time: 6 hours; Matrix: Surface/Ambient and Wastewater.

Method Name: Standard Fecal Coliform Fermentation (15 Tube MPN); Units: MPN Index/100 ml; Standard Method Number: SM 9221B and SM 9221E; Holding Time: 6 hours; Matrix: Surface/Ambient and Wastewater

Method Name: E. coli Determination (E.C. with MUG); Units: C.F.U./100 ml or MPN Index/100 ml; Standard Method Number: SM 9221F; Holding Time: 6 hours; Matrix: Surface/Ambient and Wastewater  